content of the rural eco home project content of the rural eco home project content of the rural eco home project content of the rural eco home project content of the rural eco home project content of the rural eco home project content of the rural eco home project content of the rural eco home project
envirociety.org
environment
    RURAL ECO-FRIENDLY HOUSE IN PRACTICE:
nature * economic * building * energy * ideas * engineering
   |  content (sitemap) |   | about our ecological project || contacts: thoughts and opinions for the eco project |   



 envirociety.org home
   Economical eco building and engineering
     Design of the individual radiant water heating system for one-floor house
   

Oreshak: old village, environs, nature
about our village
Oreshak

choosing a settling place in Varna region
the chronicle:
choosing a settling place
in Varna region

     

The design of the individual radiant water heating system for one-floor house

Chimney or stove with water boiler
Panel radiators
Gravitation circulation of water (without water circulation pump)

This heating system is working in a one storey country house with 3 rooms since October 2007. Fuels, that are used for the stove: firewood (oak, beech) and wood eco-firebricks.

Heating system plan

Figure 1.
The design of the radiant heating system - dimensions, pipe dimensions, connectors, devices

Figure 1. The design of the radiant heating system without water circulation pump
 

Figure 2.
The water expansion tube design, the element of the radiant heating installation.

Figure 2. The water expansion tube design of the radiant heating installation
 

Heating system devices, elements, materials, heating system dimensions

(from the stove boiler, hot branch)

On Figure 1:
S1 - 9 kilowatts boiling stove, hot pipe (3/4 inch screw). First room.
Th - thermometer 0-120 degrees C.
C1 - right angle galvanized (coated with zinc) iron connector (3/4 inch female screw - 3/4 inch female screw).
P1 - galvanized iron pipe, diameter 3/4 inch, length 600 mm, 2 * 3/4 inch male screw.
C2 - galvanized iron connector 3/4 in + 1/2 in + 1/2 in female screw; metallic connector 1/2 inch to 20x2 mm PE/AL/PE pipe.
F1, P2 - faucet; metallic connector 1/2 inch to 20x2 mm; pipe to the outdoor underground heat accumulator, PE-MD/AL/PE-MD B-pipe (polyethylene-aluminium-polyethylene pipe for heating systems), diameter 20 * 2 mm, pressure 10 Bars.
P3 - PE-MD/AL/PE-MD B-pipe (polythene-aluminum-polythene pipe), diameter 20 * 2 mm, pressure 10 Bars. Lenght 1420 mm.
C3 - connector 3xB-pipe 20 * 2 mm
P4 - see below in specification of Figure 2.
P5 - B-pipe 20x2 mm, pressure 10 Bars. Length 1870 mm.
C4 - connector "B-pipe 20x2 mm"-1/2 inch to the heating radiator R1
R1 - two-face panel radiator 600x600 mm, effective heat area is about 3 square metres, power is approximately 2...3 KW. Second room.
V1, V2 - DC 12-Volts 0.2 Ampers ventilators, for additional air convection.
F2 - 1/2 inch air faucet, from radiator.
T1 - tup, 1/2 inch.
C5 - connector 1/2 inch - "B-pipe 20x2 mm" from the radiator R1
P6 - B-pipe 20x2 mm, pressure 10 Bars. Length 890 mm, the slope of the pipe is 40 mm / 890 mm
C6 - connector "B-pipe 20x2 mm"-1/2 inch to the heating radiator R2
R2 - two-face panel radiator 600x600 mm, effective heat area is about 3 square metres, power is approximately 2...3 KW. Third room.
V3, V4 - Direct current 12-Volts 0.2 Ampers ventilators, for convection of cold air from the floor.
F3 - 1/2 inch air faucet, from radiator.
T2 - tup, 1/2 inch.
C7 - metallic connector 1/2 inch - "B-pipe 20x2 mm" from the radiator R2
P7 - B-pipe 20x2 mm, pressure 10 Bars. Length 4830 millimetres.
C8 - connector 3x"B-pipe 20x2 mm"
F4, P8 - faucet; metallic connector 1/2 inch to 20x2 mm; pipe to the heat energy accumulator, PE-MD/AL/PE-MD pipe, diameter 20x2 mm, pressure 10 Bars.
C9, F5, P9 - metallic connector 1/2 inch - pipe 20x2 mm; faucet; pipe to the WC.
P10 - galvanized iron pipe, diameter 1/2 inch, length 600 mm, 2 x 1/2 inch male screw.

On Figure 2:
P4 (from Figure 1) - pipe to the expansion tube, diameter 20x2 mm, length 1 meter. The pipe consists of one transparent segment - transparent pipe with neckband connection.
C11 - connector 2x"B-pipe 20x2 mm"-10 mm pipe
P11 - pipe-condenser, 20x2 mm B-pipe. Length 2.7 meters.
P12 - vertical pipe-narrow, 10x1 mm copper pipe. Length 200 mm.
C12 - connector diameter 10mm - "B-pipe 20x2 mm" with neckband
P13 - B-pipe 20x2 mm. Length ??? mm.
C13 - connection with the expansion tube - by steel segment and neckband.
E1 - 10 litres expansion tube with water level indicator (wl) inside the heating system.
wl - water level inside the heating system.

 

  >> More articles - part Economical eco building and engineering  

 
 
     
>> How we use "free energy" from renewable sources
underground heat accumulator
building of the underground heat accumulator

 
 
opposite to nannospalax leucodon
our opposite to nannospalax leucodon
(underground rodent)
       
   |  content (sitemap) |
 
 envirociety.org home
   Economical eco building and engineering
     The design of the individual radiant water heating system for one-floor house
     
Ecophotos of nature and people


 
 
 
| about our ecological project || contacts: thoughts and opinions for the eco project |   
 
eco project logo  envirociety.org

 
Creative Commons License
This work is licensed under a Creative Commons Attribution-Share Alike 3.0 License.
 
envirociety.org, 2007 - 2010