logo of the rural ecoproject               society
content of the rural eco home project content of the rural eco home project content of the rural eco home project content of the rural eco home project content of the rural eco home project content of the rural eco home project content of the rural eco home project content of the rural eco home project
envirociety.org
environment
    RURAL ECO-FRIENDLY HOUSE IN PRACTICE:
nature * economic * building * energy * ideas * engineering
   |  content (sitemap) |   | about our ecological project || contacts: thoughts and opinions for the eco project |   



 envirociety.org home
   Economical eco building and engineering
     Construction of underground heat accumulator
   

Oreshak: old village, environs, nature
about our village
Oreshak

choosing a settling place in Varna region
the chronicle:
choosing a settling place
in Varna region

     

"Free energy" from renewable sources.

 

It is necessary in the current environment
 >>  Compliance with nature environmental laws - self-defense - self-sufficiency - independence - biological shelter. Self '.'
Self-defense, self-sufficiency, self... Independence, freedom and ecological shelter; as the essence of SAMoDOM.

 

Calculation of kinetic energy of the wind upon our parcel

The formula for full wind kinetic power:

W=0.5*Ro*A*(V**3),

where:

W is full kinetic power of wind flow [Watt]
Ro is air density (1.225 kilograms per cubic metre)
A is area [square metre]
V is wind speed on the area A [metre per second]

See Wikipedia
Wind power
Wind turbine design

Maximal available area upon parcel is 46 metres length x 8 metres height (line east-west), minimal area is 12 metres length x 8 metres height (line south-north) - 96 sqm. For minimal air area, wind power is:

wind speed
m/s
kinetic wind power
KWatt
31.59
43.76
57.35
612.70
720.17
830.11
942.87
1058.80
1178.26
12101.61
13129.18
14161.35
15198.45
16240.84
17288.88
18342.92
19403.31
20470.40

Average wind speed for the parcel is (approximately) 4 metre per second; average wind power is 3.76 kilowatts.
Energy per year is 33000 kilowatt-hours (KWh).

Ground head energy under our parcel
(Geothermal energy)

Ground heat capacity: 0.8 KJ/(Kg*K)
Ground mass for 10 m depth: 12000 tonnes
Temperature at the depth of ten metres: 10 degrees C
If we will cool the ground to 0 degree C or will heat it to 20 degrees C, geothermal energy will be 96000 Mega Joules.

For half a year (opposite phase of ground-air temperature) energy per day is:
527 MJ per day or
22 MJ per hour or
heat power 6.1 KW

Air heat energy under the parcel

Heat capacity of air: 1 KJ/(Kg*K)
Density of air is about 1.2 kg/m3>
Air mass upon the parcel for altitude 10 m: 8160 kg
Heat energy (heating/cooling air mass to 10 degrees C): 81.6 MJ
For wind 4 metre per second: every 6.5 seconds - "new air mass" - heat power is 12 MegaWatts.

Solar power

Parcel area is 680 sqm.
Year average solar power (clear sky, during day) is approximately 800 Watts/m2 (for land area). If during 1/3 of days are clouds or fog (days without direct sunlight): solar energy (year average and day average) is 180 KWatt.

Attention

All data are approximate!

  >> More articles - the part Economical eco building and engineering  

 
 
     
>> How we use "free energy" from renewable sources
underground heat accumulator
building of the underground heat accumulator

 
 
opposite to nannospalax leucodon
our opposite to nannospalax leucodon
(underground rodent)
       
   |  content (sitemap) |
 
 envirociety.org home
   Economical eco building and engineering
     Underground heat accumulator construction
     
eco photos nature and people


 
 
 
| about our ecological project || contacts: thoughts and opinions for the eco project |   
 
ecoproject logo  envirociety.org

 
Creative Commons License
This work is licensed under a Creative Commons Attribution-Share Alike 3.0 License.
 